HEBU HFIT-T

Englisch 14 Englisch 15 GB Art.-No. HF 9518 Power Supply 100 – 260 Vac, 50-60 Hz Power Consumption max. 108 VA (100 Vac) / 100 VA (230 Vac) HF-Power output 60 W (150 Ohm) 268 Vss/95 Veff Nominal HF-frequency 500 kHz Adjustable Parameters HF-Power in W, Treatment time in s, Flow rate in ml/h, Temperature in °C (only when using the temperature probe), Synchronization (P-Z-F) ON/OFF, Automatic (P-F) ON/OFF, Program memory for nine Programs. Visualization of applied Parameters Real-Time Impedance monitoring, Total Energy input, Operating temperature (only when using the temperature probe), Voltage in V, Current in mV, Power in W, Impedance in Ohm Dimensions L x H x W = 350 x 370 x 145 mm Weight 8,1 kg Art.-No. HF 9518-01 Power Consumption max. 23 VA Feed rate 0,1 – 200 ml/h for 50ml syringe, controlled over HF-Generator via RS 232 interface Dimensions L x H x W = 330 x 120 x 155 mm Weight 2,4 kg Art.-No. HF 9529 Dimensions L x H x W = 420 x 420 x 850 mm Weight 28 kg EU Directive 93/42/EEC ( CE 0123) HF-Generator Perfusion pump Trolley Norm HEBU HFiT®-T Technical Data Ordering Data HF 9518-00 HEBU HFiT®-T with Temperature control (HF 9518), Perfusion Pump (HF 9518-01), RS 232 Interface cable (HF 9418-02), Trolley (HF 9529), Double foot switch for HEBU HFiT®-T (HF 9537-02) HEBU HFiT®-T-System HF 9945-15 HEBU HFiT®-T Needle Electrode, ø x shaft length x electrode length: 2,0 x 150 x 15 mm HF 9945-20 HEBU HFiT®-T Needle Electrode, ø x shaft length x electrode length: 2,0 x 150 x 20 mm HF 9946-15 HEBU HFiT®-T Needle Electrode, ø x shaft length x electrode length: 2,0 x 200 x 15 mm HF 9946-20 HEBU HFiT®-T Needle Electrode, ø x shaft length x electrode length: 2,0 x 200 x 20 mm HF 9946-25 HEBU HFiT®-T Needle Electrode, ø x shaft length x electrode length: 2,0 x 200 x 25 mm HF 9946-30 HEBU HFiT®-T Needle Electrode, ø x shaft length x electrode length: 2,0 x 200 x 30 mm Needle Electrodes, sterile packed Cables HF 9526-05 Potential equalization cable, 0,5 m HF 9526-10 Potential equalization cable, 1,0 m HF 9526-30 Potential equalization cable, 3,0 m HF 9569-30 Cable for disposable return plates, 3,0 m HF 9569-50 Cable for disposable return plates, 5,0 m HF 9571-30 Monopolar cable for HEBU HFiT®-T Needles, sterilisable, 3,0 m HF 9572-30 Bipolar cable for HEBU HFiT®-T Needles, sterilisable, 3,0 m HF 9979-01 Mains cable, e.g. for Germany, France, Austria, Scandinavia, 2,5 m HF 9979-02 Mains cable for Switzerland, 2,5 m HF 9979-03 Mains cable, e.g. for Taiwan, Korea, USA, Canada, 2,5 m HF 9979-04 Mains cable for Italy, 2,5 m HF 9979-05 Mains cable for Great Britain, 2,5 m HF 9979-06 Mains cable for Argentina and Australia, 2,5 m Accessories HF 9518-01 Perfusion Pump for 50 ml syringe, 0,1 – 200 ml/h HF 9418-02 RS 232 Interface cable HF 9529 Trolley HF 9537-02 Double foot switch for HEBU HFiT®-T-system, class AP, 6 Pin plug, cable length 4,5 m HF 9564 H Single-use security electrode neutral with double separated contact surface, Hydrogel, Conductive area 110 cm2, 50 pcs per carton HF 9949-00 Temperature probe, Type K, ø 0,5 mm, with cable, 3 m, sterilisable HF 9949-01 Y-connector for insertion of the Temperature probe into the HEBU HFiT®-T Needle and for connection of the perfusion hose, 5 pcs per carton HF 9949-02 Connection hose with Luer-Lock-Connection, 1,9 m, 25 pcs per carton HF 9949-03 Syringe 50 ml, 50 pcs per carton

RkJQdWJsaXNoZXIy MzExOTg1Mw==